Last updated: November 24, 2026

CAN Analog Input

CAN Analog Input lets a numeric value from a CAN frame be used as a virtual ADC channel — just like a voltage signal from a physical sensor.

Useful for reading values from CAN devices (for example a pressure sensor or position sensor) and connecting them to the ECU sensor configuration without extra wiring.


How It Works

The value from the CAN frame is converted to a virtual voltage (0–5V), then processed by the ECU using the configured sensor calibration.


Configuration in TunerStudio

Open: CAN Bus → CAN Input → CAN Analog Input

There are 8 channels (EFI_ADC_48 to EFI_ADC_55). For each channel:

Parameter Description
CAN ID CAN frame ID of the source device. Leave empty to disable.
Byte Offset Byte position in the CAN payload (0–7)
Data Type 8-bit or 16-bit
Byte Order Big Endian or Little Endian
Scale Multiplier to get the voltage value (Volts)
Offset Value added after multiplying
Target Channel Destination virtual ADC channel (EFI_ADC_48 to EFI_ADC_55)

Once the slot is configured, select that channel in the settings of the sensor you want (for example: MAP sensor → select EFI_ADC_48).

Tip

The conversion result is a voltage (Volts). Adjust Scale and Offset so the raw CAN value produces a voltage that matches the configured sensor curve.


Example: Fuel Pressure Sensor via CAN

The sensor sends pressure in bar × 100 as 16-bit on CAN ID 0x420, bytes 2–3:

CAN ID       = 0x420
Byte Offset  = 2
Data Type    = 16-bit
Byte Order   = Little Endian
Scale        = 0.00005   (10000 counts = 5V)
Offset       = 0
Target       = EFI_ADC_48

Then in the fuel pressure sensor configuration, select EFI_ADC_48 as the input.