Last updated: November 24, 2026
CAN Analog Input¶
CAN Analog Input lets a numeric value from a CAN frame be used as a virtual ADC channel — just like a voltage signal from a physical sensor.
Useful for reading values from CAN devices (for example a pressure sensor or position sensor) and connecting them to the ECU sensor configuration without extra wiring.
How It Works¶
The value from the CAN frame is converted to a virtual voltage (0–5V), then processed by the ECU using the configured sensor calibration.
Configuration in TunerStudio¶
Open: CAN Bus → CAN Input → CAN Analog Input
There are 8 channels (EFI_ADC_48 to EFI_ADC_55). For each channel:
| Parameter | Description |
|---|---|
| CAN ID | CAN frame ID of the source device. Leave empty to disable. |
| Byte Offset | Byte position in the CAN payload (0–7) |
| Data Type | 8-bit or 16-bit |
| Byte Order | Big Endian or Little Endian |
| Scale | Multiplier to get the voltage value (Volts) |
| Offset | Value added after multiplying |
| Target Channel | Destination virtual ADC channel (EFI_ADC_48 to EFI_ADC_55) |
Once the slot is configured, select that channel in the settings of the sensor you want (for example: MAP sensor → select EFI_ADC_48).
Tip
The conversion result is a voltage (Volts). Adjust Scale and Offset so the raw CAN value produces a voltage that matches the configured sensor curve.
Example: Fuel Pressure Sensor via CAN¶
The sensor sends pressure in bar × 100 as 16-bit on CAN ID 0x420, bytes 2–3:
CAN ID = 0x420
Byte Offset = 2
Data Type = 16-bit
Byte Order = Little Endian
Scale = 0.00005 (10000 counts = 5V)
Offset = 0
Target = EFI_ADC_48
Then in the fuel pressure sensor configuration, select EFI_ADC_48 as the input.